CMR-B-scalar sensors module for high pulse magnetic field measurement
Specifications:
- CMR-B-scalar sensor based on polycrystalline (La-Sr-Mn-O) films and colossal magnetoresistance (CMR) effect;
- It is able to measure a magnetic induction of up to 40 T independently on its direction;
- The sensor active volume is 400 μm × 50 μm × 0.4 μm;
- Sampling rate 0.73 MSa/s;
- Remotely controlled from PC;
- Optical data transfer line;
- 2 D and 3D sensors array possibilities.
|

|
|
Commercial CMR-B-scalar magnetic field meter
Applications: Pulse magnetic field measurement in to electric power systems and high efficiency electromotors.
Specifications:
- It is able to measure a magnetic induction in the (0,2 - 5) T range independently on its direction.
- Frequency range up to 10 kHz;
- Sampling rate 2 MSa/s;
- Data storage possibility in to SD card.
Magnetic field sensors includes:
1) CMR-B-scalar sensor;
2) Pt-1000 temperature sensor.
Magnetic field meter
|
Magnetic field sensors
Magnetic field meter
|
|
Nanoelectroporator
Applications: Biotechnologies:
- Microbial transformation;
- Mammalian cell transfection;
- Protein transfection;
- Enhance extraction of cell proteins;
- Microbial decontamination.
Medicine:
- Enhance drug delivery to cancer and pathological cells or organism;
- Induction of local intracellular signal;
- Induction of cell migration.
Specifications:
- Pulse rise time – 100 ns;
- Pulse fall time– 300 ns;
- Pulse duration – 3 μs ÷ 10 ms;
- Pulse amplitude – 100 ÷ 4000 V;
- Single and repetitive signals generation.
|
 |
|
Frequency converter
Purpose – speed and torque control of AC induction motors. Frequency converter is introduced in serial production in JSC “Tamona”.
Specifications:
- Motor power – up to 4kW.
- Supply – three-phase 50/60Hz, 400V.
- Output voltage frequency – adjustable, (0–100) Hz.
- Adjusting of speed (output voltage frequency) – by hand, using keyboard; automatic in feedback control system.
|
 |
Be the first to know the news