Ionizing radiation

No.

Service

Remarks

1

Calibration of ionization chambers (dose calibrators) used in nuclear medicine

Traceability for the following radionuclides: 18F, 67Ga, 90Y, 99mTc, 111In, 123I, 125I, 131I, 137Cs,

153Sm, 177Lu, 201Tl, 223Ra

2

Calibration of radiometers (gamma-ray spectrometers)

Atomtex AT1320, BRIGHTSPEC, and equivalent

3

Calibration of dose rate meters (monitors)

Rados RDS-30, RaySafe, Atomtex AT1125, and equivalent; up to 5 points

4

Calibration of surface contamination meters

Contamat and equivalent; up to 5 points

5

Calibration of sources of ionizing radiation

β, γ, α emitters / point and plate (e. g., disk-shaped) sources

6

Determination of activity concentration of radionuclides in water

γ emitters; performed from 2 litres

7

Determination of bulk activity of tritium in water

Performed from 0.5 litre

8

Determination of activity concentration of radio-carbon (14C) in water

Performed from 1 litre; prices for other matrices – up to agreement

9

Determination of activity concentration of radio-nickel (63Ni) in water

Performed from 1 litre; prices for other matrices – up to agreement

10

Determination of activity concentration of radio-strontium (89/90Sr) in water

Performed from 1 litre; prices for other matrices – up to agreement

11

Determination of activity concentration of plutonium (238Pu, 239/240Pu)  in water

Performed from 5 litres; prices for other matrices – up to agreement

12

Production of a sample for testing

Ash of bio-fuel, bio-fuel (chipped wood), and other matrices

13

Production of an unquenched scintillating solution in the standard geometry of an LSC vial

3H, 14C, 36Cl, 63Ni, 90Sr+90Y, 99Tc, 129I, 137Cs

14

Calibration of a gamma-ray spectrometer with an HPGe detector

In the range of 46.5 keV – 2615 keV for a selected geometry

15

Calibration of a liquid scintillation counter  (spectrometer)

3H, 14C, 36Cl, 90Sr+90Y, 99Tc

16

Calibration of an alpha- spectrometer

234U, 238U, 241Am, 242Pu

Uncertainties for the measurements with capabilities declared in the Key comparison database of BIPM can be found via this link. Having selected the entries of interest (or having pressed the button „SELECT ALL“), press the button „EXPORT XLS“.

Upon the customer’s request, corrections to the operation of the customer’s device may be introduced, if possible.

To order a calibration or another service, please contact the head of the Ionizing Radiation Metrology Laboratory, Mr. Arūnas Gudelis, phone: +370 5 264 4855, +370 620 17793.