Notes. Prices specified do not include VAT. Customers ordering several calibrations are entitled to a discount.
Uncertainties for the measurements with capabilities declared in the Key comparison database can be found via this link. Having selected the entries of interest (or having pressed the button „SELECT ALL“), press the button „EXPORT XLS“.
To order a calibration, please contact the head of the Temperature Standard Laboratory, Mr. Kęstutis Mikalauskas, phone: +370 652 81317.
No. |
Service |
Remarks |
1 |
Dissemination of the UTC(LT) time-scale to subjects of the Lithuanian economy (with continuous control of metrological traceability) |
The service is provided via the NTP and PTP protocols |
2 |
Calibration of frequency counters |
Frequency is measured directly. Frequency range: 1 Hz – 200 MHz |
3 |
Calibration of frequency generators |
Frequency is measured directly. Frequency range: 1 Hz – 200 MHz |
4 |
Calibration of frequency generators |
The method of time-phase difference is applied. Calibration is performed at the fixed frequency points: 100 kHz, 1 MHz, 5 MHz, 10 MHz |
5 |
Calibration of time difference sources and meters as well as pulse width sources and delay lines |
Range: 0 s – 1 s |
6 |
Calibration of GPS receivers |
|
7 |
Calibration of mechanical time measurement devices |
|
8 |
Calibration of digital time measurement devices |
|
9 |
Assessment of characteristics of signal generators in frequency and time domain |
|
10 |
Assessment of temporal characteristics of digital oscilloscopes |
|
11 |
Calibration of experimental and non-standard time measurement devices |
|
Uncertainties for the measurements with capabilities declared in the Key comparison database can be found via this link. Having selected the entries of interest (or having pressed the button „SELECT ALL“), press the button „EXPORT XLS“.
Calibrations are carried out at a room temperature, under the normal conditions.
To order a calibration, please contact the head of the Time and Frequency Standard Laboratory, Mr. Rimantas Miškinis, phone: +370 5 2620194.
Service |
Range(s) |
Calibration of a standard resistor |
1 mΩ – 1 TΩ |
Calibration of a resistor set |
1 Ω – 1 GΩ |
Calibration of a high resistance resistor set |
1 GΩ – 1 TΩ |
Calibration of an ohmmeter, voltmeter, multimeter, or a calibrator |
1 Ω – 1 TΩ, 0,1 V – 1000 V (DC), 0,1 V – 1000 V (10 Hz – 1 MHz), 100 μA – 100 mA (DC) |
Calibration of a resistance bridge |
1 Ω – 1 GΩ |
Calibration of a DC voltage source of two nominal values against a Zener or the primary (Josephson) voltage standard |
1.018 V, 10 V |
Calibration of an AC (from 10 Hz to 1 MHz) voltage source |
2 mV – 1000 V |
Calibration of a DC current source |
100 μA – 100 mA |
Uncertainties for the measurements with capabilities declared in the Key comparison database of BIPM can be found via this link. Having selected the entries of interest (or having pressed the button „SELECT ALL“), press the button „EXPORT XLS“.
Calibrations are carried out at a temperature specified by the customer in the range from 18 oC to 26 oC.
To order a calibration, please contact the responsible person of the Electrical standards laboratory, Mr. Andrius Bartašiūnas, phone: +370 5 261 8065.
No. |
Service |
Range |
1 |
Calibration of contact comparators for gauge blocks |
|
2 |
Calibration of standard and working gauge blocks of the highest precision |
(0.5-100) mm |
3 |
Calibration of micrometers –MK, MZ types, and digital ones |
(0-100) mm |
4 |
Calibration of callipers |
(0-1000) mm |
5 |
Calibration of dial indicators of the IČ type and digital ones with the division value of 0.001 mm, 0.002, and 0.01 mm |
(0-50) mm |
6 |
Calibration of indicators with the division value of 0.002 mm |
(0-2) mm |
7 |
Calibration of indicators with the division value of 0.001 mm |
(0-1) mm |
To order a calibration, please contact the head of the Length Standard Laboratory, Mrs. Lilija Chaleckienė, phone: +370 612 16739.
No. |
Service |
Remarks |
1 |
Calibration of ionization chambers (dose calibrators) used in nuclear medicine |
Traceability for the following radionuclides: 18F, 67Ga, 90Y, 99mTc, 111In, 123I, 125I, 131I, 137Cs, 153Sm, 177Lu, 201Tl, 223Ra |
2 |
Calibration of radiometers (gamma-ray spectrometers) |
Atomtex AT1320, BRIGHTSPEC, and equivalent |
3 |
Calibration of dose rate meters (monitors) |
Rados RDS-30, RaySafe, Atomtex AT1125, and equivalent; up to 5 points |
4 |
Calibration of surface contamination meters |
Contamat and equivalent; up to 5 points |
5 |
Calibration of sources of ionizing radiation |
β, γ, α emitters / point and plate (e. g., disk-shaped) sources |
6 |
Determination of activity concentration of radionuclides in water |
γ emitters; performed from 2 litres |
7 |
Determination of bulk activity of tritium in water |
Performed from 0.5 litre |
8 |
Determination of activity concentration of radio-carbon (14C) in water |
Performed from 1 litre; prices for other matrices – up to agreement |
9 |
Determination of activity concentration of radio-nickel (63Ni) in water |
Performed from 1 litre; prices for other matrices – up to agreement |
10 |
Determination of activity concentration of radio-strontium (89/90Sr) in water |
Performed from 1 litre; prices for other matrices – up to agreement |
11 |
Determination of activity concentration of plutonium (238Pu, 239/240Pu) in water |
Performed from 5 litres; prices for other matrices – up to agreement |
12 |
Production of a sample for testing |
Ash of bio-fuel, bio-fuel (chipped wood), and other matrices |
13 |
Production of an unquenched scintillating solution in the standard geometry of an LSC vial |
3H, 14C, 36Cl, 63Ni, 90Sr+90Y, 99Tc, 129I, 137Cs |
14 |
Calibration of a gamma-ray spectrometer with an HPGe detector |
In the range of 46.5 keV – 2615 keV for a selected geometry |
15 |
Calibration of a liquid scintillation counter (spectrometer) |
3H, 14C, 36Cl, 90Sr+90Y, 99Tc |
16 |
Calibration of an alpha- spectrometer |
234U, 238U, 241Am, 242Pu |
Upon the customer’s request, corrections to the operation of the customer’s device may be introduced, if possible.
To order a calibration or another service, please contact the head of the Ionizing Radiation Metrology Laboratory, Mr. Arūnas Gudelis, phone: +370 5 264 4855, +370 620 17793.
1. Development, optimization, and validation of new calibration and measurement methods according to the requirements of the international standard ISO/IEC 17025.
2. Measurements of amount of substance/concentration in different matrices, with metrological traceability ensured, by the following methods:
4. Organization and assessment according to requirements of the international standard ISO 17034 of interlaboratory comparisons (ILC) and proficiency tests (PT).
5. Consultations on various issues of chemical measurements and metrological traceability as well as ensuring quality in the field of chemistry.
To order a calibration or another service, please contact the responsible person of the National Standard of Amount of Substance, Mr. Evaldas Naujalis, phone: +370 5 261 2758, +370 698 04035.